Polar Parts

Ships to CanadaPrices in CAD

MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 2 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 3 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 4 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 5 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 6 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 7 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 8 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 9 of 10
MQ-2, MQ-3, MQ-7 and MQ-135 Gas Sensor Modules, image 10 of 10
Image 1 of 10

MQ-2, MQ-3, MQ-7 or MQ-135 Gas Sensor Module, Smoke, Alcohol and CO Detection

$7.20

5+ $6.76 each · 10+ $6.32 each

Shipping timeline confirmed during order processing

Free shipping when eligible items total $20+. Otherwise est. $3.15

In stock

Supplier stock is confirmed at checkout.

Option: MQ-2
Quantity
Sold by
Polar Parts
Ships from
Our supplier partnersSupport from Milton, Ontario
Shipping
Canada only
Returns
14 days, unopened items
Payment
Secure checkout

Add to cart as a guest. You'll sign in at checkout, before payment.

About this part

Analog gas sensor modules in four versions, each aimed at a different gas, for DIY kits and gas detector projects. Pick the MQ-2 for smoke and flammable gases, the MQ-3 for alcohol, the MQ-7 for carbon monoxide, or the MQ-135.

  • MQ-2: smoke and flammable gases such as liquefied gas, butane, propane and methane, 300 to 10000 ppm
  • MQ-3: alcohol (ethanol), 10 to 1000 ppm
  • MQ-7: carbon monoxide, 10 to 1000 ppm
  • MQ-2 and MQ-3 heaters run at 5.0V ±0.2V, drawing up to 180mA (900 mW)
  • MQ-2 and MQ-3: response within 10 s, recovery within 30 s, for use from -20 to 55 °C

Use them for experiments and learning, not in place of a certified smoke or CO alarm.

Specifications

BrandEstardyn
TypeGas Sensor
MaterialPolymer
UseGas Sensor
OutputAnalog Sensor
TheoryHall Sensor
SKUPP-80E99F4F-MR01

Supplier description

Provided by the supplier. Our shipping, returns and support terms apply.

MQ-2 Sensor Model: MQ-2 Gas: smoke Detection range: 300 to 10000ppmm Characteristic gas: 1000ppmm isobutane Sensitivity: R in air/Rin typical gasge5 Sensitive body resistance: 1KOmega to 20KOmega in 50ppm toluene Response time: le10s Recovery time: le30s Heating resistance: 31 Omega plusmn 3 Omega Heating current: le180mA Heating voltage: 5.0V plusmn 0.2V Heating power: le900mW Measuring voltage: le24V Working conditions Ambient temperature: -20 deg C ~ +55 deg C Humidity: le95% RH Environmental oxygen content: 21% Storage conditions Temperature: -20 deg C ~ +70 deg C Humidity: le70%RH Applications: Household and factory gas leak monitoring devices suitable for detection of liquefied gases, butane, propane, methane, alcohol, hydrogen, fumes, etc. MQ-3 Sensor Gas: Alcohol (ethanol) Detection range: 10 ~ 1000ppm alcohol Characteristic gas: 125ppm alcohol Sensitivity: R in air/Rin typical gasge5 Sensitive body resistance: 1 ~ 20KOmega in air Response time: le10s (70% Response) Recovery time: le30s (70% Response) Heating resistance: 31 Omega plusmn 3 Omega Heating current: le180mA Heating voltage: 5.0V plusmn 0.2V Heating power: le900mW Measuring voltage: le24V Ambient temperature: -20 deg C ~ +55 deg C Humidity: le95% RH Environmental oxygen content: 21% Storage temperature: -20 deg C ~ +70 deg C Storage humidity: le70%RH MQ-7 Sensor Product model: MQ-7 Product type : Semiconductor gas sensor Detection gas: carbon monoxide Detection concentration: 10-1000ppmCO Loop voltage: le10V DC Heating voltage (VH): 5.0V plusmn 0.2V ACorDC (high) 1.5V plusmn 0.1VACorDC (low) Heating time (TL): 60plusmn1S (high) 90plusmn1S (low) Load resistance (RL): adjustable Heating resistance (RH): 31Omega plusmn 3Omega (room temperature) Heating power consumption (PH): le350mW Sensitive surface resistance (Rs): 2KOmega-20KOmega (in100ppmCO) Sensitivity (S); Rs (in air) / Rs (100ppmCO) ge 5 Concentration slope (alpha): le 0.6 (R300ppm/R100ppmCO) Temperature, humidity: 20 deg C plusmn 2 deg C; 65% plusmn 5% RH Standard test circuit: Vc: 5.0V plusmn 0.1V; VH (high): 5.0V plusmn 0.1V; VH (low): 1.5V plusmn 0.1V Warm-up time: no less than 48 hours MQ135 Sensor Product model: MQ135 Product Type: Semiconductor Gas Sensor Detection gas: ammonia, sulfide, benzene vapor Detection concentration: 10-1000ppm (ammonia, toluene, hydrogen) Loop voltage (Vc): le24V DC Heating voltage (VH): 5.0V plusmn 0.2V ACorDC Load resistance (RL): adjustable Heating resistance (RH): 31 Omega plusmn 3 Omega (room temperature) Heating power consumption (PH): le900mW Sensitive surface resistance (Rs): 2KOmega-20KOmega (in 100ppm NH3) Sensitivity (S): Rs (in air) / Rs (100ppm NH3) ge 5 Concentration slope (alpha): le 0.6 (R100ppm/R50ppmNH3) Temperature, humidity: 20 deg C plusmn 2 deg C; 65% plusmn 5% RH Standard test circuit: Vc: 5.0V plusmn 0.1V; VH: 5.0V plusmn 0.1V Warm-up time: no less than 48 hours

ESP32 vs Arduino vs Raspberry Pi: which board for your project

What the Arduino Uno, ESP32 and Raspberry Pi are each good at, where each struggles, and what else you need to buy to get one running.

Shipping & returns

Delivery
Ships from suppliers outside Canada. Shipping timeline confirmed during order processing. Tracking is shared when available.Shipping policy
Shipping cost and tax
This item is eligible for free shipping: eligible items in your cart ship free once they total $20 or more. Carts of many low-priced parts need more than $20, and the cart shows how much. Under that, shipping is estimated at $3.15 from a supplier quote and quoted live for your Canadian address at checkout. Sales tax is added there too, so you see the full total before you pay.
Returns
Unopened, unused items in resalable condition can be returned within 14 days of delivery. Some items are excluded.Refund policy
Questions before you order?
Ask about fit, compatibility or bulk quantities.support@polarparts.caContact support
See all